Monitoring of Volatile Organic Compounds for Wastewater Discharge Facilities in the Nakdong River Basin |
낙동강 수계 폐수배출업소를 대상으로 휘발성유기화합물질 배출실태 조사 |
이인정, 임태효, 허성남, 이재관, 이용희, 이호열, 천세억 |
국립환경과학원 |
|
Abstract |
There are many industrial factories in the central Nakdong river basin and have been occurred water pollution accidents by hazardous chemicals such as phenol, 1,4-dioxane and perchlorate. In this study, seven volatile organic compounds, VOCs(1,3-butadiene, vinyl acetate, ethyl acrylate, epichlorohydrin, styrene,hexachloroethane, 1,4-dioxane) potentially discharged into the Nakdong river were determined by purge & trap and gas chromatography-mass spectrometry(GC-MS). Method detection limit(MDL) and limit of quantitation(LOQ) were in the range 0.14~0.38 μg/L and 0.44~1.22 μg/L, respectively. Six compounds(1,3-butadiene,vinyl acetate, ethyl acrylate, epichlorohydrin, styrene, 1,4-dioxane) were detected in wastewater treatment plants(WWTPs) and wastewater discharge facilities from the Nakdong River basin. 1,4-Dioxane was most frequently observed in WWTPs and wastewater discharge facilities. |
Key Words: